Seasonal lighting tool

Christmas Tree Light Bulb Checker

Find which part of your Christmas lights failed, whether it is safe to switch them on again, and the exact fix, in four questions.

4 questions UK fuse ratings Safety verdict No sign-up

Calculator Inputs

The wattage and the maximum number of sets to connect are printed on the label or the box of your set — enter 1 string's watts, not the total for the chain. The fuse rating is stamped on the plug itself, and the checker only ever compares your load against that rating.

Not sure what you have? Pull 1 bulb out: if it comes free of its holder it is an incandescent mini, and if the bulb is moulded into the cable the set is an LED string. Change the first answer above and the fault reading changes with it.

Calculation Breakdown

Step Reading Result
Light typeSelected set type-
SymptomWhat happens at the switch-
ChainStrings linked end to end-
LoadWatts ÷ 230 V-
Fuse ceilingFuse rating × 230 V-
VerdictFault rule for this symptom-

Scenario Analysis: Your Chain Against Both Fuse Ratings

Setup Total Watts Current Fits 3 A (690 W) Fits 5 A (1,150 W)
1 string----
2 strings----
3 strings----
4 strings----
Your setup----

A 3 A fuse caps the circuit at 690 W and a 5 A fuse at 1,150 W, both at 230 V. The larger ceiling is not a reason to fit a larger fuse: the rating stamped on the plug is the one the cable was sized for. If the table says your chain fits comfortably, the fuse is not what is making your lights fail.

What To Do Next

1

Switch off, then unplugTurn the switch off before you pull anything, and pull the plug rather than the flex. A cable tugged by its wire strains the 1 connection that carries every bulb on the set.

2

Read the plug and check the fuseThe rating is stamped on the plug — 3 A or 5 A in ordinary use. Fit 1 fuse of exactly that rating; never substitute the 13 A fuse that came in the same box of spares.

3

Work the symptom, not the whole setSwap the first dark bulb, push every other bulb fully home, or inspect the cable where a section goes dark. Doing all 3 at once tells you nothing about which 1 of them fixed it.

4

Read the label before you link anythingTwo numbers live there: the watts for 1 string, and the maximum number of sets the manufacturer allows in 1 chain. Both belong in the inputs above.

5

Retest 1 string at a timePlug in 1 set alone, then add the others back 1 by 1. The first set that kills the fault is the set that carries it, which a linked chain can never show you.

6

Retire a set that repeats the fault2 fuse changes or 2 dead sections in 1 season means the set, not the bulb, is failing. The figures on a replacement set matter more than the count of bulbs on the box.

What The Checker Decides

6 symptoms cover almost every failure you will see on a household light set: 1 dead set, 1 dark bulb, a dark section, a dim or discoloured glow, flicker or cut-out, and heat. The checker reads the symptom together with the type of set — sealed LED, plug-in incandescent mini, or large screw-in C7/C9 — because the same symptom means a different fault on each of those 3 types. It also runs a separate load check: watts per string multiplied by the number of strings, divided by 230 V, then compared with the 690 W a 3 A fuse allows or the 1,150 W a 5 A fuse allows.

Why One Bulb Switches Off The Whole String

Incandescent mini sets are wired in series, so 1 bulb's filament sits in the path of every other bulb on that run — break it and the run goes dark. Each bulb carries a shunt that bridges the break, which is why 1 dead bulb often leaves the rest glowing while the shunt holds the circuit together. A shunt is a holding measure, not a repair, so replace the dark bulb in the same session: the 2nd filament to fail may meet a shunt that has already given up. LED strings behave the other way round, because the LEDs sit in parallel, so 1 dark LED leaves the other 99 on a 100-LED set running and a whole dark section points at the cable rather than at a bulb.

The Plug Fuse Does Two Different Jobs

A BS 1363 plug takes 1 of 2 cartridge fuses in ordinary use: 3 A, which caps the circuit at 690 W at 230 V, or 5 A, which caps it at 1,150 W. The 13 A fuse reaches 2,990 W at 230 V, and it belongs in plugs stamped 13 A rather than in a plug marked 3 A. The fuse protects the cable, not the lights: it opens once the current passes its rating, before the flex reaches a temperature that starts a fire. That distinction decides the diagnosis — a set that is hot, buzzing or smells of burning can sit far below 690 W and still be dangerous, because the fault there is a joint rather than the total.

Chained Strings And The 230 V Load

Power in watts is voltage multiplied by current, so 230 V at 1 A is 230 W, at 3 A it is 690 W and at 5 A it is 1,150 W. The label on the set states both the watts for 1 string and the maximum number of sets allowed in 1 chain — the 2 numbers that together decide whether your setup sits inside the fuse you have. Enter them and the table shows the same chain at 1, 2, 3 and 4 strings: at 40 W a set, 4 strings draw 160 W and 0.70 A, which is 23% of a 3 A ceiling, so the fuse is not your problem. A chain that trips its fuse the moment you switch on is reporting a fault somewhere in the run, not asking for a bigger fuse.

Replace With The Same Bulb, Not A Similar One

Buy spares matching the type and the wattage printed on the original box, because a replacement with a different rating changes the share of the 230 V each bulb in a series run receives. Screw-in C7/C9 bulbs match by base and wattage, while mini bulbs match by base shape and the voltage marking on the glass — the 2 figures a shop assistant needs. Mixed bulbs in 1 series run show up as a set that glows unevenly or burns through its spares inside a single season. Keep the box: the watts per string and the maximum chain length are usually printed on it, and those are exactly the 2 numbers the load check above requires.

Method and limits

Method. The fault verdict is a lookup rather than a measurement: your 5 answers select 1 row of the published fault table, and that row supplies the cause, the safety reading, the time and the parts. The load check is arithmetic — strings × watts per string, then ÷ 230 V for amperes, compared against fuse × 230 V for the ceiling. Both appear in the Calculation Breakdown so you can audit them by hand.

  • Assumes the wattage entered is for 1 string and is printed on the set's own label — a figure carried over from a different set understates the whole chain.
  • Assumes the sets are linked end to end into 1 socket — an extension lead, a second socket or a timer puts more cable between the plug and the lights, and none of that is visible here.
  • Does not model a controller box, a transformer-fed indoor set, a solar set or a 12 V low-voltage set — those fail differently, and none of the 6 symptom rules was written for them.
  • Does not test your lights — it cannot see a cracked cable, a scorched contact or water sitting in a connector, so any of those outranks the verdict shown.
  • Does not override the maximum chain length on the label, which is a manufacturer limit this tool has no way to read.
  • Does not decide product compliance: CoryVu is independent, is not affiliated with any manufacturer or retailer named on this page, and cannot confirm whether a set meets any safety standard.

Figures checked .

When To Stop Using The Set

Heat, a burning smell, a scorch mark, a cracked plug or a tingle when you touch the flex ends the diagnosis: unplug at the socket and replace the set, because neither a 3 A nor a 5 A fuse will stop a joint that has already started to burn. The HSE advises an RCD rated at no more than 30 mA for portable and outdoor supplies, and that device is the backup that limits the energy in a shock rather than a reason to keep a damaged set running. Trimming a cable, taping a flex or fitting a larger fuse to keep a set alive removes the protection the plug was marked with, and none of those 3 repairs is one you can undo at the end of the season. Bring outdoor sets indoors while the connectors are wet: water in a socket turns up as flicker, a dim glow or a tripping circuit, and all 3 of those readings mean inspect before reuse.

Frequently Asked Questions

Why is one bulb dark but the rest of the string still works?

On an incandescent mini set the bulbs sit in series, and each bulb carries a shunt that bridges the gap when its filament breaks. That shunt is why the other bulbs stay lit while this one is dark: the current is running around the dead filament instead of through it. The shunt is a holding measure rather than a repair, so replace the dark bulb in the same session — when the 2nd filament fails the shunt may not cover it, and the whole run goes out.

Which fuse goes in a UK plug for Christmas lights?

Whichever rating is stamped on the plug itself, which is 3 A or 5 A on a domestic BS 1363 plug. The 2 ratings are not interchangeable in intent: 3 A caps the circuit at 690 W at 230 V and 5 A caps it at 1,150 W, and the plug is marked with the one its cable was sized for. Fitting a 13 A fuse — 2,990 W at 230 V — into a plug stamped 3 A removes that protection, and a fuse that blows the moment you switch on is reporting a fault rather than causing one.

How many strings can I plug into one socket?

The set's own label states the maximum number of sets allowed in 1 chain, and that number is the first limit, because end-to-end sets share 1 run of cable. The second limit is the fuse: the scenario table shows a 1-string, 2-string, 3-string and 4-string chain against both the 690 W and the 1,150 W ceiling, so you can see which limit bites first. Unplug the chain and test 1 string on its own whenever anything goes wrong, because a linked chain cannot tell you which member of it failed.

Does one failed LED make the whole string unsafe?

Not by itself. A single dark LED on a set that otherwise works is a parallel run doing its job, and the set's electrical load does not change when 1 LED drops out. The safety question is separate from the fault: heat, a burning smell, a scorch mark or a cracked cable outrank any dead bulb, and those readings end with unplugging the set rather than replacing a bulb.

Sources

Last updated: 2026-10-25. This checker gives general guidance from the answers you enter. It does not test your lights and it is not a substitute for a qualified electrician.

Last updated: . Working out what a set of lights costs to run? The electric heater running cost calculator turns watts into a running cost.

About this tool

Created and maintained by CoryVu. Read how we check our tools and consult the sources and assumptions on this page.

Something unclear or incorrect? Report an issue.