Campsite Electric Hook-Up Calculator
Build your appliance combination and check it against your pitch's 5A, 6A, 10A or 16A electric hook-up before you trip the site's breaker.
Calculator Inputs
Load Breakdown
| Appliance | Watts | Share Of Load |
|---|---|---|
| Kettle | - | - |
| Toaster | - | - |
| Microwave | - | - |
| Hairdryer / straighteners | - | - |
| Electric heater | - | - |
| Fridge / coolbox | - | - |
| Other continuous loads | - | - |
| Total load | - | 100% |
Scenario Analysis
| Scenario | Total Load | Remaining Capacity |
|---|---|---|
| Your current combination | - | - |
| Kettle + heater on High together | - | - |
| Fridge and other loads only | - | - |
| Next size up hook-up | - | - |
Safe Hook-Up Timeline
Check your pitch's supply ratingAsk at reception or check the bollard for its amp rating before connecting.
Connect with a rated hook-up leadUse a lead rated for your supply, fully uncoiled to avoid overheating.
Build your appliance combination aboveCheck what you plan to run together against the supply limit.
Stagger high-draw appliancesAvoid running the kettle, heater, toaster, microwave and hairdryer at the same time.
Reset the breaker if it tripsReduce your load first, then reset at the bollard or ask the site warden.
How Campsite Hook-Up Amps Work
Power (in watts) equals voltage multiplied by current: at the UK's standard 230 V mains supply, a 10A hook-up gives 230 V × 10 A = 2,300 W, and a 16A hook-up gives 3,680 W, according to the Camping and Caravanning Club's electricity guide. Everything you run at once — kettle, heater, fridge, chargers — has to add up to less than that figure, or the pitch's breaker trips.
What Can You Actually Run?
Low-power items like lighting, phone chargers, a TV and a fridge or coolbox (around 100 W) use relatively little of even a 10A supply's 2,300 W budget. High-draw items are the problem: a kettle at roughly 2,200 W, a hairdryer or straighteners at roughly 1,200 W, and an electric heater anywhere from about 1,000 W on Low to 3,000 W on High, per Heatable's appliance running costs guide. Running two high-draw items together is what usually causes a trip.
The Kettle-And-Heater Trap
A kettle (≈2,200 W) plus a heater on Medium (≈2,000 W) already totals 4,200 W before the fridge or anything else is counted — nearly double a 10A supply's 2,300 W limit, and still over even a 16A supply's 3,680 W once other loads are added. Either appliance alone usually fits comfortably; the combination rarely does. Staggering them — boil the kettle, then switch the heater back on — is the simplest fix.
Electrical Safety On Hook-Up
Campsite bollards are outdoor, wet-location supplies, and the HSE recommends a residual current device (RCD) rated at no more than 30 mA for exactly this kind of connection — it limits the energy in an electric shock and can be lifesaving, though it's a backup measure, not a reason to ignore the load limit. If your combination trips the breaker, the Caravan Club notes it may need the site warden to reset it, not just you.
Method And Limits
Method. Supply capacity in watts is 230 V multiplied by the selected amp rating. Total load is the sum of every appliance you select at its representative wattage, plus any other continuous loads you enter. Remaining capacity is supply capacity minus total load; when that goes negative, the combination exceeds the pitch's rated supply and would be expected to trip the site's protective device.
What this tool does not model: inrush/start-up current (a fridge compressor or some heaters draw a short spike above their running wattage at switch-on); voltage drop over a long or thin hook-up lead, which reduces usable power before you reach the rated amps; your exact appliance ratings, which may differ from this tool's representative figures; and the site's actual posted rating, which can vary by pitch.
Figures checked .
Frequently Asked Questions
How many amps is a UK campsite hook-up?
UK sites most commonly offer 10A or 16A, according to the Camping and Caravanning Club's electricity guide, with 16A now standard at many modern sites and 10A common on older or budget ones. Smaller or more rural sites sometimes offer only 6A, and a small number of budget or European-style pitches offer just 5A.
How many watts is a 10 amp hook-up?
230 V × 10 A = 2,300 W. That's roughly the output of a single household wall socket, according to the Camping and Caravanning Club, which is why running a kettle and a heater together so easily exceeds it.
How many watts is a 16 amp hook-up?
230 V × 16 A = 3,680 W. Even at 16A, the Camping and Caravanning Club notes this has to cover everything at once — water heating, space heating, the microwave, the kettle and everything else plugged in.
What can I run on a 10 amp campsite hook-up?
Low-power items — lighting, phone chargers, a TV, a fridge or coolbox — use relatively little of a 2,300 W budget and can generally run together comfortably. High-draw items — a kettle (≈2,200 W), toaster, microwave, hairdryer or heater — each use most or all of the remaining capacity on their own, so avoid overlapping two of them at once.
What appliances use the most electricity while camping?
Kettles (≈2,200 W), electric heaters (up to ≈3,000 W on their highest setting), hairdryers/straighteners (≈1,000–2,200 W), toasters and microwaves (≈600–1,500 W) are the biggest draws, per Heatable's appliance running costs guide. TVs, chargers, lighting and fridges use comparatively little.
What happens if I use too much electricity on a campsite hook-up?
The pitch's residual current device or breaker trips, cutting power to your bollard until it's reset — sometimes only by the site warden, according to the Caravan Club's guide to hooking up to the mains. It's a safety device doing its job, not a fault, but it can mean losing power (and a fridge full of food) until someone can reset it.
Why does running the kettle and heater together trip the breaker?
Because together they can draw more than double a 10A supply's 2,300 W budget — a kettle (2,200 W) plus a heater on Medium (2,000 W) alone total 4,200 W before anything else is even switched on. Either appliance fits comfortably on its own; running them at the same time is the single most common way a pitch's breaker trips.
Should I get a 10A or 16A hook-up adapter?
If your site only offers 10A, a 16A adapter doesn't increase the actual supply — it just lets a 16A-rated caravan plug into a 10A bollard, and the 10A limit (2,300 W) still applies. Always match your usage to the site's actual rated supply, not the rating of your cable or adapter.
Does my fridge use much of my hook-up's capacity?
Not much on its own — a running fridge or coolbox typically draws around 100 W, one of the Camping and Caravanning Club's "low-powered" categories, alongside lighting, TVs and phone chargers. It's the combination with a kettle, heater, toaster, microwave or hairdryer that causes an overload, not the fridge by itself.
Can I run a hairdryer and a kettle at the same time on a 10A hook-up?
Usually not comfortably. A hairdryer at roughly 1,200 W plus a kettle at roughly 2,200 W totals about 3,400 W — well over a 10A supply's 2,300 W — so stagger them rather than running both together.
Is 5A hook-up enough for a caravan or motorhome?
Only for genuinely low-power use — 5A gives just 1,150 W, enough for lighting, charging and a fridge, but not enough headroom for a kettle, heater or hairdryer without exceeding it immediately. 5A is more common on European sites than UK ones, but some UK budget pitches still offer it.
What voltage do UK campsites supply?
UK campsite hook-ups supply standard UK mains voltage, 230 V, the same as a household socket — it's the amp rating (5A/6A/10A/16A) that limits how much power you can draw, not the voltage.
Does a long hook-up lead reduce how much I can run?
It can. A long or thin lead causes voltage drop between the supply post and your caravan, which reduces the power actually available before you even reach the pitch's rated amp limit — a separate wiring consideration from the appliance load this tool checks.
Why do campsite hook-ups always use an RCD?
Because they're outdoor, wet-location electrical supplies, and the HSE advises using a residual current device rated at no more than 30 mA in exactly these conditions — an RCD limits the energy in an electric shock and can be lifesaving, though it's a backup safety measure, not a substitute for not overloading the circuit in the first place.
Is this tool the same as an electrician's load calculation?
No. This is a planning estimate using typical appliance wattages, not a certified electrical assessment. If you're wiring a static caravan, converting a van, or have any doubt about your hook-up lead or connections, get it checked by a qualified electrician.
Sources
- The Camping and Caravanning Club — Campsite Electricity
- Caravan Club — Hooking up to the mains
- Heatable — Appliance Running Costs 2026
- Morphy Richards — How Many Watts Does a Kettle Use?
- HSE — Electrical safety FAQs (RCD guidance)