UK driveways & landscaping tool

Driveway Gravel & Rock Coverage Calculator

Work out how many bulk bags of gravel and MOT Type 1 sub-base your driveway needs, with a depth and sub-base check for vehicle traffic.

75-100mm Driveway Depth Check MOT Type 1 Sub-Base Free To Use Instant Results UK Focused

Calculator Inputs

Optional: Material Prices

Leave either of these blank to skip the cost estimate - no default prices are assumed.

Materials Breakdown

Step Calculation Result
Driveway areaEnter your driveway length and width above-
Gravel volume (with waste)--
Gravel--
Sub-base--

Gravel Type Scenario Analysis

Gravel Type Density Tonnes Needed Bulk Bags
Pea shingle/gravel1.5 t/m³--
Golden gravel/chippings1.7 t/m³--
Slate chippings1.4 t/m³--

Laying A Gravel Driveway: Step By Step

1

Excavate and edgeDig out to your combined sub-base plus gravel depth, and fit edging (gravel grid, timber or metal restraint) to stop gravel migrating.

2

Lay and compact the sub-baseSpread MOT Type 1 sub-base and compact it firmly with a wacker plate, in multiple passes in different directions.

3

Add a weed membraneLay a permeable weed-suppressant membrane over the compacted sub-base before the gravel layer.

4

Spread the gravelTip and rake the gravel evenly to your target depth, working from the far end back towards the access point.

5

Level and settleRake level and, for some gravel types, lightly compact or roll to help the gravel settle and interlock.

6

Maintain over timeRake periodically to redistribute gravel, top up thin patches, and clear any weeds that establish at the edges.

What Is A Driveway Gravel And Rock Coverage Calculator?

A driveway gravel calculator works out exactly how many bulk bags of gravel and MOT Type 1 sub-base you need for a gravel driveway - checking that your depth is actually adequate for vehicle traffic along the way, not just running length x width x depth like most generic gravel calculators. Enter your driveway's size, pick a gravel type and depth, and get bag counts you can take straight to a builders' merchant or aggregate supplier.

How Is The Materials Quantity Calculated?

The calculator first works out your driveway's area (length x width), then multiplies by your chosen gravel depth to get a volume, adds your waste margin, then applies your chosen gravel type's density (1.4-1.8 t/m³ depending on type) to get tonnes and bulk bags. If you include a MOT Type 1 sub-base, the same waste-adjusted approach is applied to its own volume and a compacted-density figure to get sub-base tonnes and bulk bags.

Getting The Depth And Sub-Base Right

75-100mm of surface gravel is the widely recommended range for a driveway, with 75mm as the commonly cited minimum to resist wheel-rutting under vehicle traffic - a 50mm depth is fine for paths and borders but not recommended here. A compacted MOT Type 1 sub-base (100-150mm, up to 200mm on poor ground) is also widely recommended: it distributes vehicle weight across the full area and is what stops gravel sinking or rutting over time, per Mainland Aggregates' gravel driveway construction guide.

Method And Limits

This calculator assumes a simple rectangular driveway area with a consistent depth throughout, and treats gravel and sub-base as separate, independently-priced layers. Depth and density figures are widely used UK trade rules of thumb from HowMuchGravel.co.uk's depth guide and cross-checked supplier sources, not values from a single official standard - actual bulk density varies by aggregate source and moisture content.

  • Does not model edging or restraint systems - gravel grids, timber or metal edging needed to stop gravel migrating are a separate purchase not calculated here.
  • Does not model drainage design or planning permission rules - these depend on your specific property and local authority.
  • Does not assess genuinely poor or unstable ground beyond the simple firm/poor sub-base depth choice offered - that needs a groundworks professional's assessment.
  • Uses a single density per gravel type - your specific supplier's aggregate may vary from the mid-point figures used here.

Figures checked .

Common Mistakes When Laying A Gravel Driveway

Getting the depth wrong - particularly under-specifying on a driveway - is one of the most common causes of gravel project failures according to UK aggregate supplier guidance. Other common mistakes include skipping the sub-base to save cost (leading to sinking and rutting), forgetting edging so gravel spreads onto lawns or paths, skipping a weed membrane, and forgetting a waste margin and running short mid-job.

What Happens Next?

Use the bag counts above to order your gravel and sub-base, check the exact bag weights with your own supplier (they vary by quarry), excavate and fit edging first, then lay and compact the sub-base and a weed membrane before spreading the gravel to your target depth. Get a groundworks professional's advice for anything beyond a standard domestic driveway, particularly on poor or unstable ground.

Frequently Asked Questions

How deep should gravel be for a driveway?

75-100mm of surface gravel over a compacted sub-base is the widely recommended depth range for a driveway, with 75mm as the commonly cited minimum needed to resist wheel-rutting under vehicle traffic. A shallower 50mm depth is fine for paths, borders or decorative mulch, but is explicitly not recommended for a driveway that vehicles will drive and park on.

Do I need a sub-base under a gravel driveway?

Yes - a compacted MOT Type 1 sub-base (typically 100-150mm, up to 200mm on poor ground) is widely recommended under a gravel driveway. It distributes vehicle weight across the full area and prevents the gravel sinking, rutting or disappearing into soft ground over time, which is the most common cause of gravel driveway failures according to UK aggregate supplier guidance.

What's the difference between pea shingle, golden gravel and slate chippings?

They're different decorative aggregate materials with different bulk densities and appearances: pea shingle/gravel is rounded and typically around 1.4-1.6 t/m³, golden gravel/chippings is angular and typically around 1.6-1.8 t/m³ (denser, so you need slightly more tonnage for the same depth and area), and slate chippings is flatter and typically around 1.3-1.5 t/m³. Choose based on the look you want and check your specific supplier's exact density, since it varies by quarry.

How much does a bulk bag of gravel weigh?

A standard bulk ("jumbo" or "builder's") bag of gravel or aggregate holds around 0.85 tonnes - this calculator's figure - though some suppliers quote a slightly different weight (commonly 800kg-1000kg), so check the exact figure with whoever you're buying from, since it directly affects how many bags you need to order.

How much gravel do I need per square metre?

It depends on your chosen depth and gravel density, not a single fixed figure - as a rough guide, standard 20mm gravel at a 50mm depth covers roughly 12 m² per tonne, but a driveway's recommended 75-100mm depth needs proportionally more tonnage per m² than a shallower path or border depth. Enter your own dimensions above for an exact figure.

Can I lay gravel directly onto soil without a sub-base?

You can, but most UK aggregate supplier and landscaping guides don't recommend it for a driveway - without a compacted sub-base, gravel tends to sink into the ground over time, especially under vehicle weight, meaning you'll need to top it up more often and it will never sit as firm or level as a properly built-up driveway. A sub-base is a bigger upfront cost but saves ongoing maintenance.

Should I use a weed membrane under my gravel driveway?

A permeable weed-suppressant membrane laid between the sub-base and the gravel layer is commonly recommended - it stops weeds growing up through the gravel while still letting water drain through, and it also helps keep the gravel and sub-base layers separate so they don't mix together over time. It isn't calculated by this tool since it doesn't change your gravel or sub-base quantities.

Does this calculator include the cost of edging or a driveway entrance dropped kerb?

No - this calculator only prices the gravel and sub-base aggregate itself. Edging (gravel grids, timber or metal restraint edging), a dropped kerb, and any groundworks like excavation or removing an old surface are separate costs not included here.

How much waste margin should I add?

10% is a commonly used default that covers typical spillage, compaction loss, and minor over-dig. Use a higher margin (15%) for an irregularly shaped driveway, rougher or sloped ground, or if you want a comfortable buffer rather than an emergency mid-job trip to the merchant.

What if my driveway isn't a simple rectangle?

This calculator assumes a simple rectangular driveway (length x width). For an L-shaped, curved, or otherwise irregular driveway, split it into two or more rectangles, calculate each separately, and add the resulting bag counts together - or use the largest bounding rectangle as a conservative over-estimate if the shape is only slightly irregular.

Do I need planning permission for a gravel driveway?

Usually not for resurfacing an existing driveway with permeable gravel, but rules depend on the driveway's size, whether it's a new area of hardstanding at the front of a house, and whether it drains permeably or towards a public road - this varies by local planning authority and isn't something a materials calculator can determine for you. Check gov.uk's planning permission guidance or your local council's planning department before creating a new driveway area.

How long does a gravel driveway last before it needs topping up?

With an adequate depth and a properly compacted sub-base, a gravel driveway can last many years before needing a significant top-up, though some gradual loss (gravel migrating to edges, being tracked onto roads or paths) is normal and typically addressed with periodic raking and occasional top-ups rather than a full re-lay.

Is loose gravel suitable for a driveway with heavy or frequent vehicle use?

Loose gravel at an adequate depth (75-100mm+) over a proper sub-base copes reasonably well with normal car use, but very heavy or very frequent vehicles (delivery lorries, campervans parked long-term) benefit from a deeper gravel layer (closer to 100mm) and a more substantial sub-base - check with a professional if your driveway needs to handle unusually heavy or frequent loads.

Can I mix different gravel types on the same driveway?

You can, though most UK driveway installations use a single aggregate type for a consistent appearance and predictable coverage. If you do want to mix types (e.g. a border of one aggregate around a different main area), calculate each area separately with its own density for an accurate total.

Is this calculator structural or groundworks advice?

No. It estimates materials from widely used UK trade depth and density guidance for a standard domestic gravel driveway. It is not a substitute for a groundworks professional's assessment on poor or unstable ground, drainage design, or planning permission considerations, which depend on your specific project and local authority.

Sources

Last updated: 2026-08-05. This page gives a materials-quantity estimate only and is not groundworks or drainage design advice.